Integral Fire Sprinklers
0798 358 2725
01685 370590
www.integfs.co.uk
Daytime
Message
Evening
Contact
Installation
Blazemaster Tubing
Why Integral Fire Sprinklers Use BlazeMaster® Tubing?
The Lubrizol Corp. pioneered the use of nonmetallic piping
in fire sprinkler systems The product name is BlazeMaster®
and it has been a large influence on the increased popularity
by reducing the installation cost for fire sprinkler systems
dramatically by offering an unbeatable combination of
dependability, performance and cost-
Blazemaster pipe and fittings are resistant to corrosion and have aw frictional coefficient compared to metal making it ideal for the high flow rates associated with fire sprinkler systems.
Blazemaster tube and fittings offer a high tolerance to heat with good smoke and flame characteristics. It is a fast, clean system to install because the glued joints eliminate the need for open torches on site.
When the pipe work is secured and the fire sprinkler heads fitted, the entire system is wet pressure tested to 8bar. Every joint is visually inspected for leaks and the system left under pressure until it is connected to the water main supply or fire pump set.
Domestic & Residential Sprinkler System Installation
Sprinkler System Installation
Typical fire sprinkler installations will use Blazemaster CPVC pipe work and concealed fire sprinkler heads. The pipe work and sprinkler heads are installed in accordance with the design drawings. The pipe work is secured to the structure and glued together with solvent cement.
It is preferable for the fire sprinkler heads to be fitted as part of the first fix, to allow for pressure testing of the whole system, prior to it being closed up by ceilings/floors. Each sprinkler head is fitted accurately to ensure the sprinkler cover plate sits flush to the finished ceiling.
A minimum ceiling void of 150mm is required when concealed sprinkler heads are installed.
Very low environmental impact.
Compatibility of Blazemaster
BlazeMaster® Pipe & Fittings have been tested exhaustively to ensure that they are compatible chemically with a range of products used within the building industry, which includes thread sealants, and fire stopping products.
There is a list of compatible products on the BlazeMaster® website
Blazemaster tube-
Blazemaster tube-
How does BlazeMaster tubing work?
When exposed to a very high temperature, the chemical consistency of the tube is such that it forms a charred layer which in turn, insulates the tube from any further effects of the fire.
It is important to point out however, that the tube must be fully charged with water to ensure that it functions to its maximum potential